Watkins Wellness 74427 Circulation Pump
Excluded Brands
The following brands are not eligible for LTI discount codes (including WELCOME). They go on sale only during manufacturer-authorized promotions:
- Gozney — pizza ovens and accessories
- OHCO — massage chairs
- Positive Posture — massage chairs and recliners
- Nomadix — outdoor lifestyle products (towels, blankets, accessories)
Excluded Products
The following individual products are also not eligible for discount codes:
- Any product that already has a price markdown — items on sale or clearance can't stack additional discounts on top
- FreshWater Salt System Replacement Cartridge (single)
- FreshWater Salt System Replacement Cartridge (3 Pack)
- Route Protection Insurance — third-party shipping protection, not eligible for our discounts
- Bullfrog A / R / X Series 10-00282 Filter Cartridges
- Bullfrog STIL Series 10-00281 Filter Cartridges
- FROG® @ease Sanitizer System for Bullfrog Spas
- FROG® @ease Replacement Cartridge for Bullfrog Spas (3 Pack)
- Bullfrog Simplicity™ Flat Filters for M Series (4 Pack)
- Filter Core Cage & Cap Assembly for Bullfrog Spas
- Fireplaces (gas, wood-burning, and fireplace inserts)
- Electric Fireplaces
- Gas Vent Pipe
- Pellet Vent Pipe
- Fireplace Fronts
This list can change. Manufacturers occasionally add or remove products from their MAP-protected lists. We update this page when they do, but the most accurate way to confirm whether a discount applies to a specific item is to add the item to your cart and try the code at checkout. If the code doesn't work, the item is excluded. If it does work, it's eligible.
Watkins Wellness 74427 Circulation Pump
Overview
Watkins Wellness Replacement Circulation pump replaces all Caldera & Hot Spring Spas Circulation Pump From 2002 To Current.
What's in the Box
- 1 x Watkins Wellness 74427 Circulation Pump
Specifications
- 115V
- 50-60HZ 3/4" Barb
- 5-1/2" Length
- 5" Tall
Compatibility
- Please reach out to our customer support team and they will be able to verify if this part fits your model.
Directions
Circulation Pump Removal Instructions:
- Disconnect power to the spa.
- Access the equipment compartment.
- Unplug the circulation pump from the control box.
- If the spa is filled with water, clamp the circulation pump inlet and outlet tubing with Hose Clamp Pliers.
- Remove the bonding wire and base bracket screws.
- Using Spring Clamp Pliers, slide the spring clamps located on the inlet and outlet fittings back onto the vinyl tubing.
- Remove the vinyl tubing from the pump inlet and outlet fittings.
- Disconnect the electrical cord for the old pump. Take note of the electrical hookup.
Circulation Pump Installation:
- Install the electrical cord onto the new pump.
- Reverse steps 3 to 7 of the Circulation Pump Removal instructions.
- Check for water leaks.
- Reconnect power to the spa.
- Perform a water flow test. (1 GALLON WITH 20 SECONDS)
- Check for any air in the plumbing lines. If air does not clear, bleed off the air at the closest tubing clamp.
- Reinstall the equipment compartment door.